Separation Module TS-...-1
Intended use
The TS-...-1 can be used to connect a model IT8000Ex or IT3000Ex weighing terminal to a fieldbus (Profinet, Profibus DP, Ethernet/IP or Modbus® TCP) via the intrinsically safe 10mA interface. The device also provides the power supply for the connected weighing terminal from non-hazardous areas.
ATEX approval
The TS-...-1 must not be installed in hazardous area. The internal 10mA separation module is certified for: II (2)G [Ex ib Gb] IIC (gas) II (2)D [Ex ib Db] IIIC (dust)
Power supply
100–240 V AC, 50/60 Hz.
Operating temperature
–10 °C (+14 °F) to +40 °C (+104 °F), 95 % relative humidity, non-condensing
Dimensions
W x H x D: B x H x T: 400 x 121 x 242 mm
Integrated modules
- Fieldbus module for Profinet, Profibus DP, Ethernet/IP or Modbus® TCP.
- Ex separation module TS10mAEx with intrinsically safe 10mA interface to connect to the external intrinsically safe 10mA interface of the IT8000Ex or IT3000Ex weighing terminal.
- Internal power supply unit to provide power supply for the internal components as well as the IT8000Ex or IT3000Ex weighing terminal.
- Internal Ethernet connection module with RJ45 socket to connect to IT CONFIGURATOR for service purposes
Connectivity
Fieldbus:
- TS-Ethernet/IP-1 with two M12 sockets.
- TS-Profinet-1 with two M12 sockets.
- TS-Profibus-1 via internal screw terminals.
- TS-Modbus-1 with one M12 socket
IT8000Ex and IT3000Ex:
Power supply and data line via internal screw terminals.
Options
Connection cable for Ethernet/IP / Profinet / Modbus® TCP
with M12 and RJ45 connector or two M12 connectors for non-hazardous area